XF
650
THERMOGARD™ NOMEX® Flame Retardant
Tag Material.
Description:
THERMOGARD™ 650 is a white, Nomex® flame retardant
tag material, computer-printable with dot matrix impact printers.
When used with the proper ribbon, the tag withstands many organic
solvents, and especially fluids commonly used in the aircraft
and aerospace industries.
Use: THERMOGARD™ 650 is designed as a low cost,
high performance wire bundle and cable identification tag for
use in harsh environments.
Special Properties: THERMOGARD™ 650
is a self-extinguishing material with excellent tear and solvent
resistance properties. THERMOGARD™ 650 withstands temperature
ranges from -40°F to 267°F (-40°C to 130°C). |
|
THERMOGARD™
XF 650 NOMEX®
Flame Retardant Tag Material. |
| PHYSICAL
PROPERTIES |
TEST
METHODS |
AVERAGE
RESULTS |
| |
|
USA
UNITS |
SI
UNITS |
| THICKNESS |
|
|
|
|
SUBSTRATE |
ASTM D 1000 |
0.012 in. |
0.305 mm |
|
|
|
HOLE TEAR STRENGTH |
QA
4671** |
|
|
|
MACHINE |
|
>11
lbs. |
>5
kg. |
|
CROSS |
|
>15 lbs. |
>7 kg. |
|
|
|
TENSILE STRENGTH |
ASTM D1000 |
|
|
| MACHINE |
|
185
lb/in. |
3.3
kg/mm |
| CROSS |
|
155
lb/in. |
2.8
kg/mm |
|
|
| ELONGATION |
ASTM
D1000 |
|
|
| MACHINE |
|
23% |
23% |
| CROSS |
|
126% |
126% |
| |
DIELECTRIC
STRENGTH |
ASTM
D1000 |
17,000
volts |
17,000
volts |
| |
| FLAMMABILITY |
ASTM
D568 |
ATB
= 18 sec.
AEB = .75 in. |
ATB
= 18 sec.
AEB = 19 mm. |
| ATB
= Average Time Of Burn • AEB
= Average Extent Of Burn |
|
|
All
Sl units are mathematically derived from U.S. conventional units.
Note. All values shown are averages and should not be
used for specification purposes. Test data and test results
contained in this document are for general information only
and shall not be relied upon by POLYONICS customers for designs
and specifications, or be relied on as meeting specified performance
criteria. Customers desiring to develop specifications or performance
criteria for specific product applications should contact POLYONICS
for further information |
|
| PERFORMANCE
PROPERTIES |
| TYPICAL |
TEST
METHOD |
RESULT |
Service Temperature
|
30
days at -40°F (-40°FC) |
No visible effect |
|
30
days at 105°F (40°FC) |
No visible effect |
|
1,000
hours at 275°F (135°F) |
No visible effect |
|
|
|
Print
Adherence
|
Mil
Spec. 81531 (4.5.2) |
No visible effect |
|
|
|
Weatherability
|
ASTM
D26 (QUV, 30 days) |
No visible effect |
|
|
|
Humidity
Resistance |
30
days at 100°F, 95% RH |
No visible effect |
|
|
|
Chemical
Resistance |
Samples
printed with designated ribbon, after 24 hour dwell.
The samples were immersed in the specified chemical
reagent for one minute, dried with an absorbant tissue,
followed by 30 minute recovery periods. |
No visible effect |
|
|
THERMOGARD™ XF 650 NOMEX®
|
| CHEMICAL
REAGENT |
SUBJECTIVE
OBSERVATION OF VISUAL CHANGE |
|
5
CYCLES W/O RUB |
5
CYCLES W/RUB |
Water |
No
Visible Effect |
No
Visible Effect |
| Isopropyl
Alcohol (IPA) |
No
Visible Effect |
No
Visible Effect |
10%
Sulfuric Acid Solution |
No
Visible Effect |
No
Visible Effect |
| 10%
Sodium Hydroxide Solution |
No
Visible Effect |
No
Visible Effect |
3%
Alconox® |
No
Visible Effect |
No
Visible Effect |
| MIL
5606 |
No
Visible Effect |
No
Visible Effect |
Skydrol® |
No
Visible Effect |
Slight
Print Fade |
| JP-4 |
No
Visible Effect |
No
Visible Effect |
Mineral
Spirits |
No
Visible Effect |
No
Visible Effect |
| Super
Agitene® |
No
Visible Effect |
No
Visible Effect |
1,1,1
Trichloroethane (TCE) |
No
Visible Effect |
No
Visible Effect |
| Methyl
Ethyl Ketone (MEK) |
No
Visible Effect |
Print
Completely Removed |
Toluene |
No
Visible Effect |
No
Visible Effect |
| Freon
TMS® |
No
Visible Effect |
No
Visible Effect |
ASTM
#3 Oil |
No
Visible Effect |
No
Visible Effect |
|
|
| Note.
All values shown are averages and should not be used for specification
purposes. Test data and test results contained in this document
are for general information only and shall not be relied upon
by POLYONICS or American Printing Converters customers for designs
and specifications, or be relied on as meeting specified performance
criteria. Customers desiring to develop specifications or performance
criteria for specific product applications should contact POLYONICS
or American Printing Converters for further information. |
Environmental
Tests
|
| NOTE:
All properties are typical values and should not be used for
writing specifications.
Shelf Life: 2 years at 70°F. (21°C.) and 40 to 50
% RH.
WARRANTY-LIMITATION
Polyonics’ products are sold with the understanding
that the buyer will test them in actual use and determine
for him/herself their adaptability to his/her intended uses.
Polyonics warrants to the buyer that its products are free
from defects in material and workmanship, but limits its obligation
under this warranty to replacement of the products shown to
Polyonics’ satisfaction to have been defective, provided
that the Purchaser has complied with the handling, storage
and shelf life requirements as specified by Polyonics in applicable
materials specifications. The Purchaser shall return the products
using Polyonics’ return policy as stated above.
The above warranties extend solely to Purchaser and all warranty
claims must be made by Purchaser. Rework or Replacement shall
neither extend nor decrease the original warranty period.
The term of all warranty periods shall not exceed thirty (30)
days from the date of the original shipment.
THE ABOVE WARRANTIES ARE EXCLUSIVE OF AND IN LIEU
OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED,
STATUTORY OF OTHERWISE. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY
OR OF FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY. POLYONICS
SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY
LOSS OR DAMAGE, DIRECT, INCIDENTAL OR CONSEQUENTIAL, ARISING
OUT OF THE USE OR INABILITY TO USE THE PRODUCT, OR FROM DELAY
IN THE REPLACEMENT OR REPAIR OF PRODUCTS UNDER THE ABOVE WARRANTY.
**INK RIBBONS DISCLAIMER NOTE
Polyonics, Inc. does not endorse ribbons from specific ribbon
companies. Our recommendations are based solely on the manufacturers
testing methods and procedures and are subject to revision
without further notice. |
|
| American
Printing Converters' goal is to achieve total customer satisfaction,
and we offer a 100% guarantee on all our bar code thermal
transfer ribbon products. |
|
|
| TOP OF
PAGE |
|
ASTM:
American Society for Testing and Materials (USA)
ALCONOX® is a registered trademark of Alconox Co.
FREON TMS® is a registered trademark of
DuPont, Inc. NOMEX® is a registered
trademark of DuPont, Inc. SKYDROL® is a registered
trademark of Monsanto Co. SUPER AGITENE® is a registered
trademark of Graymills Corporation. THERMOGARD™,
TRIBOGARD®, & POLYONICS are registered trademarks
of Polyonics, Inc.
|
|
|
|
|